Determination of antimony in bottled water and polyethylene terephthalate bottles: a routine laboratory quality check

The paper describes a modified and optimised conventional wet ashing method for the determination of antimony (Sb) in polyethylene terephthalate (PET) bottles used for bottling sparkling and still water. The modified optimum conventional wet ashing method was applied as the digestion method to extra...

Full description

Saved in:
Bibliographic Details
Main Authors: Brandao, Jose, Moyo, Mambo, Okonkwo, Jonathan
Format: Article
Language:English
Published: fWA Publishing 2014 2016
Subjects:
Online Access:http://hdl.handle.net/11408/1200
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1779905662986223616
author Brandao, Jose
Moyo, Mambo
Okonkwo, Jonathan
author_facet Brandao, Jose
Moyo, Mambo
Okonkwo, Jonathan
author_sort Brandao, Jose
collection DSpace
description The paper describes a modified and optimised conventional wet ashing method for the determination of antimony (Sb) in polyethylene terephthalate (PET) bottles used for bottling sparkling and still water. The modified optimum conventional wet ashing method was applied as the digestion method to extract Sb from PET bottles, and the extracted Sb analysed using flame atomic absorption spectrometry (F-AAS), and in bottled water, Sb was analysed with hydride vapour generator atomic absorption spectrometry (HVG-AAS). Microwave digestion method was also used as described above for comparison. The concentrations of Sb obtained using modified optimum conventional wet ashing and microwave digestion protocols were from 169 ± 13 to 285 ± 17 ng g-1 and from 123 ± 0.5 to 249 ± 18 ngg~1, respectively. The average concentration of Sb in bottled water samples using the HVG-AAS was 0.183 ± 0.013 pgL~1, with a range of 0.012 ± 0.001 to 0.358 ± 0.006 pg L-1. Sb concentration increased marginally with longevity of storage, but still remained well below the various guidelines for Sb levels in drinking water.
format Article
id ir-11408-1200
institution My University
language English
publishDate 2016
publisher fWA Publishing 2014
record_format dspace
spelling ir-11408-12002022-06-27T13:49:06Z Determination of antimony in bottled water and polyethylene terephthalate bottles: a routine laboratory quality check Brandao, Jose Moyo, Mambo Okonkwo, Jonathan Bottled water, digestion, microwave, PET bottles, Sb, wet ashing The paper describes a modified and optimised conventional wet ashing method for the determination of antimony (Sb) in polyethylene terephthalate (PET) bottles used for bottling sparkling and still water. The modified optimum conventional wet ashing method was applied as the digestion method to extract Sb from PET bottles, and the extracted Sb analysed using flame atomic absorption spectrometry (F-AAS), and in bottled water, Sb was analysed with hydride vapour generator atomic absorption spectrometry (HVG-AAS). Microwave digestion method was also used as described above for comparison. The concentrations of Sb obtained using modified optimum conventional wet ashing and microwave digestion protocols were from 169 ± 13 to 285 ± 17 ng g-1 and from 123 ± 0.5 to 249 ± 18 ngg~1, respectively. The average concentration of Sb in bottled water samples using the HVG-AAS was 0.183 ± 0.013 pgL~1, with a range of 0.012 ± 0.001 to 0.358 ± 0.006 pg L-1. Sb concentration increased marginally with longevity of storage, but still remained well below the various guidelines for Sb levels in drinking water. 2016-05-04T13:03:09Z 2016-05-04T13:03:09Z 2014 Article http://hdl.handle.net/11408/1200 en Water Science & Technology: Water Supply;Vol.14,No.2 open fWA Publishing 2014
spellingShingle Bottled water, digestion, microwave, PET bottles, Sb, wet ashing
Brandao, Jose
Moyo, Mambo
Okonkwo, Jonathan
Determination of antimony in bottled water and polyethylene terephthalate bottles: a routine laboratory quality check
title Determination of antimony in bottled water and polyethylene terephthalate bottles: a routine laboratory quality check
title_full Determination of antimony in bottled water and polyethylene terephthalate bottles: a routine laboratory quality check
title_fullStr Determination of antimony in bottled water and polyethylene terephthalate bottles: a routine laboratory quality check
title_full_unstemmed Determination of antimony in bottled water and polyethylene terephthalate bottles: a routine laboratory quality check
title_short Determination of antimony in bottled water and polyethylene terephthalate bottles: a routine laboratory quality check
title_sort determination of antimony in bottled water and polyethylene terephthalate bottles: a routine laboratory quality check
topic Bottled water, digestion, microwave, PET bottles, Sb, wet ashing
url http://hdl.handle.net/11408/1200
work_keys_str_mv AT brandaojose determinationofantimonyinbottledwaterandpolyethyleneterephthalatebottlesaroutinelaboratoryqualitycheck
AT moyomambo determinationofantimonyinbottledwaterandpolyethyleneterephthalatebottlesaroutinelaboratoryqualitycheck
AT okonkwojonathan determinationofantimonyinbottledwaterandpolyethyleneterephthalatebottlesaroutinelaboratoryqualitycheck