Impedimetric determination of antiretroviral drugs on a modified glassy carbon electrode
An impedimetric sensor was fabricated for the determination of determination of lamivudine (LAM) and tenofivir disoproxil fumarate (TDF) using a modified glassy carbon electrode. The glassy carbon electrode was modified with nickel-cobalt sulfide decorated graphene quantum dots (Ni-CoS-GQDs). Charac...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Institute of Electrical and Electronics Engineers Inc.
2021
|
Subjects: | |
Online Access: | https://ieeexplore.ieee.org/document/8589692/authors#authors http://hdl.handle.net/11408/4450 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1779905253729107968 |
---|---|
author | Chihava, Ruvimbo Moyo, Mambo Shumba, Munyaradzi |
author_facet | Chihava, Ruvimbo Moyo, Mambo Shumba, Munyaradzi |
author_sort | Chihava, Ruvimbo |
collection | DSpace |
description | An impedimetric sensor was fabricated for the determination of determination of lamivudine (LAM) and tenofivir disoproxil fumarate (TDF) using a modified glassy carbon electrode. The glassy carbon electrode was modified with nickel-cobalt sulfide decorated graphene quantum dots (Ni-CoS-GQDs). Characterization of the fabricated sensor was achieved by using UV-Vis, electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The LODs were 56.18 μg/ml, LAM and 56.13 μg/ml, TDF. The average recovery range was 98.85%. |
format | Article |
id | ir-11408-4450 |
institution | My University |
language | English |
publishDate | 2021 |
publisher | Institute of Electrical and Electronics Engineers Inc. |
record_format | dspace |
spelling | ir-11408-44502022-06-27T13:49:05Z Impedimetric determination of antiretroviral drugs on a modified glassy carbon electrode Chihava, Ruvimbo Moyo, Mambo Shumba, Munyaradzi Electrodes Drugs Graphene Oxidation Nickel Cobalt An impedimetric sensor was fabricated for the determination of determination of lamivudine (LAM) and tenofivir disoproxil fumarate (TDF) using a modified glassy carbon electrode. The glassy carbon electrode was modified with nickel-cobalt sulfide decorated graphene quantum dots (Ni-CoS-GQDs). Characterization of the fabricated sensor was achieved by using UV-Vis, electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The LODs were 56.18 μg/ml, LAM and 56.13 μg/ml, TDF. The average recovery range was 98.85%. 2021-06-10T11:38:28Z 2021-06-10T11:38:28Z 2018 Article 1930-0395 https://ieeexplore.ieee.org/document/8589692/authors#authors http://hdl.handle.net/11408/4450 en 2018 IEEE Sensors open Institute of Electrical and Electronics Engineers Inc. |
spellingShingle | Electrodes Drugs Graphene Oxidation Nickel Cobalt Chihava, Ruvimbo Moyo, Mambo Shumba, Munyaradzi Impedimetric determination of antiretroviral drugs on a modified glassy carbon electrode |
title | Impedimetric determination of antiretroviral drugs on a modified glassy carbon electrode |
title_full | Impedimetric determination of antiretroviral drugs on a modified glassy carbon electrode |
title_fullStr | Impedimetric determination of antiretroviral drugs on a modified glassy carbon electrode |
title_full_unstemmed | Impedimetric determination of antiretroviral drugs on a modified glassy carbon electrode |
title_short | Impedimetric determination of antiretroviral drugs on a modified glassy carbon electrode |
title_sort | impedimetric determination of antiretroviral drugs on a modified glassy carbon electrode |
topic | Electrodes Drugs Graphene Oxidation Nickel Cobalt |
url | https://ieeexplore.ieee.org/document/8589692/authors#authors http://hdl.handle.net/11408/4450 |
work_keys_str_mv | AT chihavaruvimbo impedimetricdeterminationofantiretroviraldrugsonamodifiedglassycarbonelectrode AT moyomambo impedimetricdeterminationofantiretroviraldrugsonamodifiedglassycarbonelectrode AT shumbamunyaradzi impedimetricdeterminationofantiretroviraldrugsonamodifiedglassycarbonelectrode |