The optimization of lead electrodeposition from leachant of lead laden cupels
Disposal of lead laden cupels is proving problematic to mining and metallurgical companies due to environmental and health issues. In this study the optimization of operation parameters for the electrode position of lead metal from acetic acid leachant was carried out. The effects of voltage, temper...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Open Access Library Journal
2016
|
Subjects: | |
Online Access: | http://www.scirp.org/journal/PaperInformation.aspx?paperID=69541 http://hdl.handle.net/11408/1796 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1779905278981963776 |
---|---|
author | Mpofu, IInnocencia S. Muleya, Eddwina Mutatu, Washington |
author_facet | Mpofu, IInnocencia S. Muleya, Eddwina Mutatu, Washington |
author_sort | Mpofu, IInnocencia S. |
collection | DSpace |
description | Disposal of lead laden cupels is proving problematic to mining and metallurgical companies due to environmental and health issues. In this study the optimization of operation parameters for the electrode position of lead metal from acetic acid leachant was carried out. The effects of voltage, temperature, concentration, size of electrode and the effect of the space between the electrodes were investigated. Acetic acid (10%) was used as a leachant in the optimization process. The optimum voltage was found to be 6 V, with the best operating temperature of 20°C. The amount of lead deposited increased with increase in concentration of the lead in solution up to an optimum concentration of 2271.1 ppm. However the extraction efficiencies tended to decrease with increase in concentration. The optimum inter-electrode distance was observed to be 4 cm with 0.5 cm radius electrodes that gave the largest extraction efficiency (70.9%). Acetic acid (10%) was preferred as a leachant compared to EDTA (0.1 M) because it gave higher leaching and electrode position efficiencies (73.3% vs 68.1) and (95% vs 90.8) respectively. EDTA (0.1 M) was however found to be less corrosive to the carbon electrodes as observed with acetic acid. Other advantages of acetic acid are that it is cheaper, can be obtained from renewable sources and is easy to use because there is no need for constant pH monitoring and adjustments. |
format | Article |
id | ir-11408-1796 |
institution | My University |
language | English |
publishDate | 2016 |
publisher | Open Access Library Journal |
record_format | dspace |
spelling | ir-11408-17962022-06-27T13:49:06Z The optimization of lead electrodeposition from leachant of lead laden cupels Mpofu, IInnocencia S. Muleya, Eddwina Mutatu, Washington Cupel, Leaching, Leachant, Electrode position , Aceticacid, EDTA Disposal of lead laden cupels is proving problematic to mining and metallurgical companies due to environmental and health issues. In this study the optimization of operation parameters for the electrode position of lead metal from acetic acid leachant was carried out. The effects of voltage, temperature, concentration, size of electrode and the effect of the space between the electrodes were investigated. Acetic acid (10%) was used as a leachant in the optimization process. The optimum voltage was found to be 6 V, with the best operating temperature of 20°C. The amount of lead deposited increased with increase in concentration of the lead in solution up to an optimum concentration of 2271.1 ppm. However the extraction efficiencies tended to decrease with increase in concentration. The optimum inter-electrode distance was observed to be 4 cm with 0.5 cm radius electrodes that gave the largest extraction efficiency (70.9%). Acetic acid (10%) was preferred as a leachant compared to EDTA (0.1 M) because it gave higher leaching and electrode position efficiencies (73.3% vs 68.1) and (95% vs 90.8) respectively. EDTA (0.1 M) was however found to be less corrosive to the carbon electrodes as observed with acetic acid. Other advantages of acetic acid are that it is cheaper, can be obtained from renewable sources and is easy to use because there is no need for constant pH monitoring and adjustments. 2016-09-06T08:51:37Z 2016-09-06T08:51:37Z 2016 Article 2333-9721 http://www.scirp.org/journal/PaperInformation.aspx?paperID=69541 http://hdl.handle.net/11408/1796 en Open Access Library Journal;Vol. 3 open Open Access Library Journal |
spellingShingle | Cupel, Leaching, Leachant, Electrode position , Aceticacid, EDTA Mpofu, IInnocencia S. Muleya, Eddwina Mutatu, Washington The optimization of lead electrodeposition from leachant of lead laden cupels |
title | The optimization of lead electrodeposition from leachant of lead laden cupels |
title_full | The optimization of lead electrodeposition from leachant of lead laden cupels |
title_fullStr | The optimization of lead electrodeposition from leachant of lead laden cupels |
title_full_unstemmed | The optimization of lead electrodeposition from leachant of lead laden cupels |
title_short | The optimization of lead electrodeposition from leachant of lead laden cupels |
title_sort | optimization of lead electrodeposition from leachant of lead laden cupels |
topic | Cupel, Leaching, Leachant, Electrode position , Aceticacid, EDTA |
url | http://www.scirp.org/journal/PaperInformation.aspx?paperID=69541 http://hdl.handle.net/11408/1796 |
work_keys_str_mv | AT mpofuiinnocencias theoptimizationofleadelectrodepositionfromleachantofleadladencupels AT muleyaeddwina theoptimizationofleadelectrodepositionfromleachantofleadladencupels AT mutatuwashington theoptimizationofleadelectrodepositionfromleachantofleadladencupels AT mpofuiinnocencias optimizationofleadelectrodepositionfromleachantofleadladencupels AT muleyaeddwina optimizationofleadelectrodepositionfromleachantofleadladencupels AT mutatuwashington optimizationofleadelectrodepositionfromleachantofleadladencupels |